Brand Name | Anying | Model Number | A-PH01 | Place of Origin | Guangdong, China |
---|
"Quality is Our Culture!"
Click the picture or the title to know more details.
![]() | ![]() | ![]() |
Anying Temperature & Humidity Sensor TH6? Unique design, easy to install Relay & RS485 Output with external sensor Enable Software Management | Anying Solid Moisture & Temperature Sensor High-sensitivity Enable Software Management Optional?4-20 mA, 0-2V, RS485 output Be compatible to all kinds of solid Endure?long?time?electrolysis? | Anying CO2 Sensor?SM3370M ? High sensitive?infrared?sensor?probe Self-diagnosis?function Convenient?installation?and?maintenance Optional: 4~20mA?,?0~5V?,?0~10V or RS485 output |
![]() | ![]() | ![]() |
Anying Lux Meter A-LUX1 ? Waterproof,?easy?installations Stable?remote?control 3 optional output: 0-5V/4-20mA/RS485/RS232 3 optional power supply:?220V AC/24V AC/24V?DC | Anying Conductivity Sensor A-EC01 ? High?sensitivity?and?stability 3?Options of?Output?signals: Voltage?output:0~5V?or?0~2V? Current?output:4-20mA? Digital?output:RS485 ? ? | Anying Humidity & Temperature Controller TH1 Clear LCD screen to show real-time data RS485 Output with built-in sensor Enable Software Management ? |
Industrial pH meter is upgraded intelligent product of industrial acidity meter. It can achieve continuous measurement and control of the pH of waste water.
?
This instrument could be applied to the fields of sewage treatment, chemistry, printing and dyeing, paper making, pharmacy and environmental protection, etc.
?
According to the environment and characteristics of water industry, combining international electricity supply standard, considering electrical design code of special environment, there are 3 power supply for you to choose: 220V AC or safe low voltage of 24V AC and 24V DC.
?
Signal output could also be optional:? 0-5V/4-20mA/RS485.
?
?
Main features of this product
?
Technical Parameter
Measuring range | pH(0 – 14 pH) ;ORP( -1900 - +1900 mV) |
Accuracy | +?0.02 pH;?+1 mV |
Resolution | 0.01pH; 1mV |
Stability | ≤ 0.02 pH/24 hours; ≤ 3 mV/24 hours |
pH standard solution | 4.01/6.86/9.18 |
Display mode | 128 * 64 lattice LCD |
Temperature compensation | 0–100 ℃ manual/automatic(NTC10K) |
Signal output | 4-20mA isolation protection output, maximum loop resistance 300Ω |
Alarm output | each team of high and low limit alarm contact (3A/250 V AC), contact relay regularly on |
Power supply | AC 220V±10%? 50Hz |
Power consumption | ≤3W |
Environment conditions | (1) temperature 0~?60 ℃?(2) humidity≤85%RH |
Overall size | 96×96×110mm(height×width×depth) |
Hole size | 92×92mm(height×width) |
?
?
?
?
The?OEM service?is offered if needed.