Basic Info

Brand NameSunshineModel NumberVT1K(1KS/2KS/2KS/3KS/3KS)Place of OriginChina

Product Description


Product Description




Delivery Time:2 weeks
Certification:ISO 9001,CE


Single?Phase?High?Frequency?Online?UPS?240V?36VDC



Quick Detail:


Rate Capacity:1K-3KVA
Power factor:0.8
Input:(90±5)VAC~?(300±5)VAC
Output:220Vac
Input?system:Single?phase?&?earth?ground
Voltage?precision:±2%


Specifications:



































































MODEL

VT1K

VT1KS

VT2K

VT2KS

VT3K

VT3KS


Rating



1KVA/800W

2KVA/1600W

3KVA/2400W

Input


Input?system




Single?phase?&?earth?ground




Voltage?range




(90±5)VAC~?(300±5)VAC




Power?factor




≥0.99




Voltage?range?of?bypass




(80±5)VAC~?(286±5)VAC?(default:?80VAC~264VAC?



Could?be?adjusted?by?software)




Output




Output?system




Single?phase?&?earth?ground




Rated?voltage




220VAC??①




Power?factor




0.8




Voltage?precision




±2%



Output? frequency


Normal?mode




1.The?output?frequency?synchronizes?with?the?input?frequency?



when?the?input?frequency?is?in?the?range?of??46?Hz~?54?Hz



2.The?output?frequency?is?50Hz?when?the?inpu



t?frequency?is?not?in?the?range?of?46?Hz~?54?Hz



3.Can?be?set?as?60Hz




Battery?mode




Inverter?overload?



capacity?(Utility?power,?25℃)




105%±5%<Load≤125%±5%?50s?transfer?to?bypass



125%±5%<?Load?<150%±5%?25s?transfer?to?bypass



Load?>?150%±5%,?300ms?transfer?to?bypass




Transfer?time




0ms?(Normal?mode←→?Battery?mode)




<4ms?(Normal?mode←→Bypass?mode)




Crest?factor




3:1




Battery




Batteries?voltage




36VDC



72VDC/96VDC

96VDC/72VDC


Battery?quantity




3




None




6/8




None




8/6




None




Battery?Type




Sealed?maintenance-free?lead?–acid?battery?of?battery?voltage?12V/7AH




Backup?Time?(25℃)




Full?load≥5min?(Standard)




Charge?current




1A




6.5A




1A




5.5A




1A




5.5A



①?Note1:?Output?voltage?can?be?set:?200V/208V/220V/230V/240V.