操屁精品视频在线播放,黄色视频app下载,久草视频久草中文在线,日韩成人私密一级精品av

CREATE YOUR LISTING

Epower Electronics Science Company

Main products:

Home/Products/Rechargeable Medical Infusion Pumps With 4 Hours Working Time / Ambulatory Infusion Pump/

Rechargeable Medical Infusion Pumps With 4 Hours Working Time / Ambulatory Infusion Pump

Update time:2022-02-08 14:33:42
Price:Negotiable
Min Order:1 Kilogram / Kilograms
  • 7 days
  • T/T L/C D/P D/A
  • 0 Kilogram / Kilograms per Month

Basic Info

Brand NameEpowerModel NumberXB-1000Place of OriginChina

Product Description


Product Description




Delivery Time:5-7 working days after received payment
Certification:CE/ISO

Rechargeable Medical Infusion Pumps With 4 Hours Working Time / Ambulatory Infusion Pump?


Product advantages


Bolus & KVO function.?
Button Operation history records.
Time and calendar display.
Multi-language selection: English, Spanish, Russian etc.
Infusion Modes: Time Mode,Rate Mode, ?Body Weight Mode&Drip Mode.
4.3 inches colorful LCD screen.

Technical parameters






















































Applicable infusion sets



All brands of standard infusion sets



Infusion increment



0.1ml/h



Selectable modes



Rate mode, ?Body weight mode,Time mode, Drip mode?



Injection accuracy



±3%



Body weight mode



?Dose:0.1~9999.9mg ? ? ? ? ? Weight: 0.1~300kg ?


Volume limit: 0.1~999.9ml ? ?Drug limit: 0.1~999.9mg


(Subject to unit, dosage, liquid, weight and infusion)



Infusion rate range?



1~2000ml/h



Bolus rate ?



100~1000ml/h ??



KVO rate?



Adjustable, 1ml/h~5.0ml/h ?



Time mode



Volume limit: 0.1~9999.9ml?



Time: 1~6000 minutes?



Accumulated volume



0.1~9999.9ml



Rate mode?



1~2000ml/h ?



Preset range



0.1~9999.9ml



Occlusion value



Adjustable,39.2kPa~137.2kPa, ?pressure show on the graphic



Battery



Rechargeable lithium polymer battery 7.4V, 3000mA, working for 4 hours(25ml/h) after being fully charged



Alarm function?



Air,OCCLU, over?, out of battery,?no AC power supply,drop error, CPU communication error,specification error, ?low battery, installation error, no operation remind, door open.?



Panel instructions



1,Infusion rate ?2,?Infusion preset volume 3,?Accumulated infusion volume 4,?Battery capacity ?5,Battery charging indication 6,AC power supply connection indication ?7,Over ?8,OCCL. Alarm ?9,Air 10,Bed ?11,Pressure Value ?12,Flow rate , etc.



Power supply



AC100~240V?? 50/60HZ



Max power consumption



25VA



Classification



Class II, type BF



Storage condition



?Environment temperature: -20℃~+55℃, air pressure (50~106)kPa,relative humidity≦95%



Operation condition?



Environment temperature: 5℃~+40℃,?air pressure (86~106) kPa, ?relative humidity≦80%?



EMC



Meet the requirements of IEC60601-1-2(2007 version)?



Electrical safety?



Meet the requirements of EN60601-1:1990+A1:1993+A2:1995?



Overall maximum size



125L*140W*205?Hmm



Gross weight?



less than 2.8kg



Infusion Pumps



Recommended Products

Recently Viewed

Contact Us

  • Epower Electronics Science Company

Copyright ? www.525022.com